Features GSV5
Description Versatile GSM/GPRS communicator
Product type Alarm system module

In-built wired zones on board

6
On-Board (open collector type) PGM 2
Reporting to CMS format CID by GPRS
Reporting protocols for CMS E2, FIBRO, Kodinis KSP
Compatibility with control panels via KEYBUS PC5xx, PC14xx, PC15xx, PC16xx, PC18xx
Compatibility with control panels via SERIAL SP4xxx, SP6xxx, SP7xxx, EVOxxx
Compatible with SG-SYSTEM II , III IP card Yes
Alarm message for end user SECOLINK PRO app, GSM call, SMS
Available language for voice guide

English (available other languages)

Available language for SMS

English (available other languages)

DTMF converting from PSTN to GPRS Yes (one way)
Available in plastic enclosure

Yes

Maximum current into -PGM1 -0.05 A
Maximum current into -PGM2 -0.05 A
Power supply from an independent source of power:
Maximum battery charging current +0.035 A
Rated voltage of power supply (AC) ~20 V
Minimum AC voltage ~16 V

Maximum AC voltage

(Note: higher than ~22 V voltage can damage control panel)

~22 V
Maximum current of slow blowing fuse used in primary AC 250 mA
Maximum AC power consumption 15 mA
Power supply from an Control Panel source of power:
Power supply (DC) 9 - 14 V
Current consumption 50 mA
Current consumption with all PGM's 260 mA
Overall dimensions W x H in mm 120 x 64

Environmental compliance

ROHS
Operating temperature

From -10oC to +50oC

Interface for communicator settings programming

USB

Interface for communicator firmware updating

USB