Features GSV4
In-built wired zones on board 6
RF Jamming detection Yes
PGM on board 3
User codes 5
Defaulting user code Yes
Key switch zone Yes
Partitions 1
System timers 16
Event log size 512
Reporting to CMS format CID via GPRS
Total number of protocols, used for CMS reporting E2, FIBRO, Kodinis KSP
Compatible with SG-SYSTEM II, III IP card Yes
Alarm message for end user GSM calls, SMS
Alarm message for end user by voice clip Yes
Voice guide for end user Yes
Recordable audio alarm messages Yes
Available language for SMS English, National
System remote control by GSM call Arm / disarm / clear alarm / PGM control / zone bypass
emote system control by Android smart phone application Yes
Remote system control by iPhone smart phone application 2014 Q1
Zone speed (sensitivity) 0.1 - 2.5 sec.
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL
Arming mode Away, Max Away, Night, Stay.
Zone definition

Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control;

24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature.

Zone attributes Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night.
PGM definition Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, wxit arm status, full arm status, arm/disarm acknowledge, power supply, resettable power supply, fire power supply, timer, mono/bi switch.
PGM attributes Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, arm notification, disarm notification, clear alarm notification.
Rated voltage of power supply (AC) ~20 V

Minimum AC voltage

~16 V

Maximum AC voltage

(Note: higher than ~22 V voltage can damage GSV4)

~22 V

Maximum long term output current of GSV4

(I+AUX + I+BELL + battery charge)

0.7 A
Maximum current of slow blowing fuse used in primary AC 250 mA
Maximum AC power consumption <30 mA
Minimum voltage on +AUX, +BELL, outputs 12 V
Maximum voltage on +AUX, +BELL, outputs 13.9 V
Maximum current out of +AUX 0.25 A
Maximum current out of +BELL (without battery) 0.2 A
Maximum current out of +BELL (with battery) 2 A
Maximum current into -PGM1 -0.05 A
Maximum current into -PGM2 -0.05 A
Short circuit, overload protection of +BELL, +AUX electronic
Battery charge +BELL, +AUX current measurement Yes
Failed (waste) backup battery disconnection Yes
Maximum battery charging current 0.25 A
Maximum current of fast blowing fuse used in battery 3.15 A
GSV4 disconnects battery when it’s voltage less than 9.5 V
Recommended backup power supply 12 V, 7 Ah / 20 Hr
Operational compliance EN50131, Grade2
Overall dimensions W x H in mm 120 x 64
Environmental compliance ROHS
Operating temperature From -10oC to +50oC
Interface for control panel settings programming USB
Interface for control panel firmware update USB
Remote control panel settings programming Yes, via www.alarmserver.net