fbpx
Model Possibility to connect wireless detectors Cellular communication technology Has an integrated SIM card (eSIM)  Slot for the user’s SIM card Cellular service plan Premium plan1
S16cmR    2G       Yes   1 year
S16emR   2G LTE-M     Yes   1 year
S16gmR   2G   LTE CAT1   Yes   1 year
S16cm Yes 2G       Yes   1 year
S16em Yes 2G LTE-M     Yes   1 year
S16gm Yes 2G   LTE CAT1   Yes   1 year
S16cE Yes 2G     Yes Yes 10 years2 2 years
S16eE Yes 2G LTE-M   Yes Yes 10 years2 2 years
S16gE Yes 2G   LTE CAT1 Yes Yes 10 years2 2 years
S16eW Yes 2G LTE-M   Yes Yes 10 years2 2 years

 

   1 - An activated Premium plan allows the user to control the system via internet using the SECOLINK PRO mobile app. The plan is activated or extended

by purchasing a voucher and activating it in the user's account on ALARMSERVER.NET. The voucher can be purchased at: shop.secolink.eu or from an installer or SECOLINK product distributors.

   2 - The service period begins when the system connects to the mobile network — from that moment, the duration of the service is counted. Once this

period ends, the user will be offered the option to extend the mobile connectivity service and the Premium plan for one additional year. Although the exact price after 10 years is not known, it is expected to be similar to the GSIM voucher price at that time. The current voucher price can be found at: shop.secolink.eu.

  

  

Main features of the control panel
Alarm system concept Hybrid modular system
On-board wired zones 5/10 (doubling)
2-wire smoke detector input 1
On-board wireless zones 16
Maximum zones in system 16
On-board PGM 3
Maximum PGM in system 16
User + installer codes 31+1
Duress code Yes
Defaulting user code Yes
Key switch zone Yes
Partitions 4
"Shared" partition (common area) Yes
System timers 16
Maximum keypads/modules in system 3
Keypad compatibility All SECOLINK keypads
Event log buffer 256 (with keypad 512)
Interface with transmitters and communicators of other manufacturers -
Data bus protocol KRBUS 
"Roller" detector type Yes
"Vibration" detector type Yes
"Vibration" zone speed (sensitivity) 0.01 - 0.25 sec.
Normal zone speed (sensitivity) 0.1 - 2.5 sec.
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller, Wireless
Arming mode Away, Max Away, Night, Stay.
Zone definitions Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control;
24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature
Zone attributes Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night
PGM definitions Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch
PGM attributes Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode
Remote system control and notification to user via internet
Number of recipients for internet messaging using app SECOLINK PRO  10
Requirements for system control via internet using the SECOLINK PRO app
  • the system user must create an account in the ALARMSERVER.NET cloud and register the product by entering the product identification number "BI";
  • the online service must be activated for the system;
Push notifications Yes
Notifications to the user using user's SIM card (SMS, call)
SIM slot size Micro SIM
Number of recipients for SMS, voice clip messaging  5
Alarm message for end user by voice clip Only S16gmR, S16gm
Voice guide for end user Only S16gmR, S16gm
SMS out (device >> phone) Yes
SMS in (phone >> device) Yes
SMS text language (device >> phone) Can be changed using MASCAD PRO
Operation of SECOLINK PRO using SMS services  plain text1
Reporting to Central Monitoring Station (CMS)
Reporting to CMS Yes
Reporting to CMS format CID by GPRS/LTE-M/LTE CAT1
Reporting protocols for CMS E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
Compatible with SG-SYSTEM II , III IP card Yes
Maximum load and electrical characteristics
Rated voltage of power supply (AC) ~20 V

Minimum AC voltage

(note: ~16 V input voltage lets control panel to generate max 0,5 A output current)

~16 V 

Maximum AC voltage

(Note: higher than ~22 V voltage can damage control panel)

~22
Maximum long term output current of control panel (I+AUX + I+BELL + IBATTERY CHARGE ≤0,7 A
Maximum current of slow blowing fuse used in primary AC 250 mA 
Maximum AC power consumption 150 mA
Minimum voltage on +AUX, +BELL outputs 12 V 
Maximum voltage on +AUX, +BELL outputs 13,9 V 
Maximum current out of +AUX +0,5 A
Maximum current out of +BELL +2 A
Maximum current into -PGM1 -0,15 A
Maximum current into -PGM2 -0,15 A
Short circuit, overload protection of +BELL, +AUX Electronic
Battery charge, +BELL, +AUX current measurement Yes
Failed (waste) backup battery disconnection Yes
Maximum battery charging current +0,2 A
Maximum current of fast blowing fuse used in battery circuit 2,5 A
Control panel disconnect battery when it’s voltage less than 9,5 V
Operational compliance EN50131, Grade2 
Recommended backup battery 12 V, 2,2 - 7Ah
Overall dimensions W x H in mm 145 x 77
Environmental compliance ROHS 
Operating temperature From -10oC up to +50o
Remote programming of control panel settings Yes
Production status In production
Interface with PC USB micro-B 
Latest firmware version Download
Wiring manual Download
Programming manual (for keypad KM20Bx) Download
Programming manual (for keypads KM24x, KM25) Download
 

   1 - SMS messages from the control panel are not imported into the SECOLINK PRO app - they can be viewed using the SMS editing app on the phone. Lock

icons (ARMED / DISARMED) are not displayed in the app. SMS commands are not performed in the background - SECOLINK PRO will „insert“ the control command for the user into SMS editing app and the user will need to tap on the button Send.